• <b id="6X5oBEp"></b>

        1. <legend></legend>
          <tr id="6X5oBEp"></tr>

        2. Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
          0517-86918678
          Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
          Tel:0517-86918678
          Fax:0517-86918679
          Email:zhongweick@https://themugshotcompany.com
          Post Encoding:211600

          Fluorine plastic insulation and sheath high temperature resistant cable

          氟(fu)塑料絕緣護套耐(nai)高(gao)溫(wen)電(dian)纜(lan).jpg
          • 氟(fu)塑(su)料絕緣(yuan)護套耐(nai)高(gao)溫(wen)電纜(lan).jpg
          Fluorine plastic insulated and sheathed high-temperature cable has good high temperature resistance,…

          Description:

          An overview, cables:
          Fluorine plastic insulated and sheathed high-temperature cable has good high temperature resistance, long-term between 40 ℃ - 200 ℃ with corrosive gases, such as the work under the harsh environment.And acid and alkali resistance, oil resistance and aging resistance and other characteristics, which can effectively ensure the connection between the thermocouple and the instrument and transmission signal.Used in petroleum, chemical, power generation, metallurgy and other industrial and mining enterprises, in the high temperature, low temperature and acid, alkali, oil, water and corrosion of the gas in the bad environment do electrical instrumentation and automation control system of signal transmission lines.
          Second, fluorine plastic insulation and sheath use high temperature resistant cable features:
          1, the working temperature: KFF - 200, KFP1F - 200, KFP1F22, KFP1F22-260 does not exceed 200 ℃;
          2, rated voltage Uo/U: 450/750 v and below;
          3, the lowest temperature: fixed installation - 60 ℃;
          4, the fixed installation - 20 ℃;
          5, minimum bending radius: KFF type should be.
          Three, the main technical indicators:

          projectTechnical indicators
          guide
          The body of the
          straight
          flow
          electricity
          The resistance

          0.20.350.50.751.01.52.54.06.0
          Don't tin platingTin platingDon't tin platingTin platingDon't tin platingTin platingDon't tin platingTin platingDon't tin platingTin platingDon't tin platingTin platingDon't tin platingTin platingDon't tin platingTin platingDon't tin platingTin plating
          Conductor typeClass AB92.39455.857.536.036.724.524.818.118.212.112.27.417.564.614.703.083.11
          R class////39.040.026.026.719.520.013.313.77.988.214.955.093.033.39
          Test voltageTest voltage 2500 v rated voltage 450/750 v / 1 min rated voltage up to and including 300/500 test voltage 2000 v / 1 min
          Insulation resistanceAt 20 ℃ or higher, 500 m Ω km

          Four, fluorine plastic insulation and sheath high-temperature cable type and name:

          modelThe name of thenote
          KFF-200F46 insulation and sheath high temperature resistant cableLong-term working temperature of 20 ℃
          KFP1F-200F46 insulation and sheath blocking high temperature resistant cable
          KFF22-200F46 insulation and sheath steel tape armoured high temperature resistant cable
          KFP1F22-200F46 insulation and sheath steel tape armoured shield, high temperature resistant cable

          Five, the fluorine plastic insulation and sheath high-temperature cable type:


          projectCode nameSaid Ming
          Series generation numberKControl cable
          Insulation materialsFFep (F46) highest working temperature 200 ℃
          Meltability polytetrafluoroethylene (PFA), the highest working temperature 260 ℃
          Shielding materials/
          P1
          No shielding can be omitted
          Tin plated copper wire
          Sheath materialFFep (F46) highest working temperature 200 ℃
          Meltability polytetrafluoroethylene (PFA), the highest working temperature 260 ℃
          Armoring materials22
          32
          Steel tape armoured
          Fine steel wire armoured
          Conductive coating/
          Y
          Tin plating omission
          Silver plated
          Heat resistant grades200
          260
          The highest working temperature 200 ℃
          The highest working temperature 260 ℃
          specifications
          To fill out some x conductor section (N (S)
          N:2 3 4 5 7 8 10 12 14 16 19 24 27 30 37 44 48 52
          S:0.2 0.35 0.5 1.75 1.0 1.5 2.5 4.0 6.0(mm2)℃
          Conductor type
          (in brackets)
          A
          B
          R
          Single strand conductors
          Seven strands of stranded conductor
          More flexible conductor

          Six, ordering information:
          When placing order, please indicate the type, specification, wire core section, some way, block and quantity.


          Browse:
          Return To The Top

          分亯到(dao):

          sUUgK

            • <b id="6X5oBEp"></b>

                1. <legend></legend>
                  <tr id="6X5oBEp"></tr>