          High Temperature Compensation Wire

          高溫(wen)補償導(dao)線(xian).jpg
          • 高溫補(bu)償(chang)導(dao)線(xian).jpg
          High temperature compensation wire is suitable for temperature control system of energy, metallurgy,…

          Description:

          A brief introduction, conductor:
          Temperature compensation wireThe effect is to extend the thermode that cold end of thermocouple temperature measurement system and mobile display instrument is connected.High temperature thermocouple compensation wire insulation layer and protective layer according to the environmental requirements of the selected material is not the same, PVC sheath material, fluorine plastic, low smoke and low halogen PVC and alkali free glass wire several imported high-quality fluorocarbon can be high temperature of 260 DEG C, and the continuous extrusion process, make the product has excellent acid resistance, alkali resistance, and flame extension performance, can be used for a long time in oil.
          Temperature compensation wireThe use of temperature in - 60 - 260 C, which belongs to the contemporary domestic advanced level.Series of products are mainly used in various types of temperature measuring device, according to the variety of products is divided into SC, KC, KX, EX, JX, TX, NC.
          Two, the implementation of standards: GB/T4989/94 equivalent to IEC584.3,
          Three, use range:
          Temperature compensation wireApplicable to energy, metallurgy, petroleum, chemical and other industrial enterprises and scientific research departments, the temperature control system.For the connection between the cold end temperature measuring instrument and temperature measuring instrument.Heat type imported fluorine plastic insulated and sheathed with excellent heat resistance, waterproof, anti-corrosion, anti acid, chemical resistance, resistance to abrasion, aging and combustion performance.Use temperature of -60 to 260 DEG C, is the international advanced level.
          Three, the conditions of use:
          (1): highest working temperature: heat with 200 degrees and 260 degrees two;
          General: a maximum of 70 degrees and 105 degrees two.
          (2) the lowest ambient temperature: fluorine plastic insulated and sheathed cable laying: -60 C -20 C non fixed installation;
          PVC insulated and sheathed cable laying: -40 C -15 C non fixed installation.
          (3) the minimum bending radius: PVC insulated and sheathed cable non armored cable is not less than 6 times of cable diameter, 10 times of fluoroplastic insulation and sheath for non armored cable is not less than the diameter of the cable, not less than 12 times of cable diameter for armored cable.
          Four,Temperature compensation wireThe use of characteristics:

          type

          The minimum bending radius

          The lowest temperature

          Maximum temperature

          Unarmored

          Armoured

          Fixed installation

          Non fixed installation

          General type
          There are 105 types of ""
          There are 90 types of ""
          High temperature type

          6 times of the cable diameter
          10 times of the cable diameter

          12 times of the cable diameter

          C = -40

          C = -60
           

          C = -15

          C = -20
           

          Less than or equal to 70 DEG C
          Less than or equal to 105 DEG C
          Less than or equal to 90 DEG C
          Less than or equal to 250 DEG C

          Five, product code and meaning:

          project

          Code

          Code meaning

          project

          Code

          Code meaning

          Model

          SC

          Thermocouple compensation wire, S index

          Heat resistant grade

          Seventy

          The highest temperature is 70 DEG C

          RC

          Thermocouple compensation wire, R index

          One hundred and five

          The highest temperature is 105 DEG C

          NC

          Thermocouple compensation wire, N index

          Two hundred

          The highest temperature is 200 DEG C

          NX

          Thermocouple compensation wire, N index

          Two hundred and fifty

          The highest temperature is 250 DEG C

          KCA
          KCB

          Thermocouple compensation wire, K index

          Insulating materials

          V

          polyvinyl chloride

          KX

          Thermocouple compensation wire, K index

          Y

          polyethylene

          EX

          Thermocouple compensation wire, E index

          B

          polypropylene

          JX

          Thermocouple compensation wire, J index

          F4

          Teflon

          T

          Thermocouple compensation wire, T index

          F46

          Poly perchloro ethylene propylene

          Series code

          ZR

          Flame retardant cable

          Jacket material

          V

          polyvinyl chloride

          IA

          Intrinsically safe cable

          B

          glass fibre

          The use of classification

          G

          For general use

          F4

          Teflon

          H

          heat resistant

          F46

          Poly perchloro ethylene propylene

          Precision grade

          S

          Precision

          Shielding material

          P

          Copper wire braid

          P1

          Tinned copper braid

          /

          Common grade

          P2

          Copper tape wrapped

          P3

          Aluminum / plastic composite film wrapping

          Specifications


          2 x conductor cross-sectional area mm2

          Conductor type


          Single conductor can be omitted

          R

          Stranded conductors

          Armored

          Twenty-two

          Steel tape

          Thirty-two

          Steel wire armoured

          Six, technical indicators:
          1 type alloy wire material and insulation color

          Compensation wire type

          Thermocouple

          Mark thermocouple

          Compensation lead wire

          The insulation layer of color

          Positive order

          The negative

          Positive order

          The negative

          SC

          10- Platinum Rhodium Platinum thermocouple

          S

          SPC (copper)

          SNC (Cu, Ni)

          red

          green

          RC

          13- platinum rhodium thermocouple

          R

          RPC (copper)

          RNC (Cu, Ni)

          red

          green

          KCA

          Nickel chromium nickel silicon thermocouple

          K

          KPCA (iron)

          KNCA (Cu, Ni)

          red

          blue

          KCB

          KPCB (copper)

          KNCB (Cu, Ni)

          red

          blue

          KX

          KPX (CR)

          KNX (Ni SI)

          red

          black

          NC

          Ni Cr Si Ni Si thermocouple

          N

          NPC (iron)

          NNC (Cu, Ni)

          red

          ash

          NX

          NPX (Ni Cr SI)

          NNX (Ni SI)

          red

          ash

          EX

          Nickel - copper nickel thermocouple

          E

          EPX (CR)

          ENX (Cu, Ni)

          red

          Brown

          JX

          The iron - copper nickel thermocouple

          J

          JPX (iron)

          JNX (Cu, Ni)

          red

          purple

          TX

          Copper - copper nickel thermocouple

          T

          TPX (copper)

          TNX (Cu, Ni)

          red

          white

          2, the use of protective layer of color classification

          The use of classification

          Precision grade and sign

          Jacket color

          Common grade

          Precision

          Common grade

          Precision

          For general use

          G

          /

          S

          black

          gray

          heat resistant

          H

          /

          S

          black

          yellow

          Seven, delivery requirements:
          According to both agreements, the length of measurement error is about 0.5%.
          Eight, ordering:
          In order to indicate the product name, type, number, temperature rating, shielding type, quantity etc..


          Browse:
          Return To The Top

          分(fen)亯(xiang)到(dao):

          QnWCA

            • <b id="6X5oBEp"></b>

                1. <legend></legend>
                  <tr id="6X5oBEp"></tr>