          Rosemount 3051L Flanged Installed Level Transmitter

          儸斯矇(meng)特(te)3051L灋(fa)蘭(lan)安(an)裝(zhuang)液位變送器(qi).jpg
          • 儸斯矇特(te)3051L灋蘭(lan)安裝(zhuang)液(ye)位變送(song)器(qi).jpg
          Ross Monte 3051L flange mounted liquid level transmitter Due to the adoption of ASIC amplifier desig…

          Description:

          Productoverview:
          Ross Monte 3051L flange mounted liquid level transmitter Due to the adoption of ASIC amplifier design to make the packaging becomes small, and the miniaturization of the membrane structure and the flange of the box, this type of weight dropped to half of the original type. ASIC design not only reduces the number of parts, but also improve the reliability of the amplifier.
          Two, work principle:
          When working, the high and low pressure side of the diaphragm and the filled liquid transmit the process pressure to the filling liquid filled liquid, then transmits the pressure to the center of the sensing diaphragm sensor. The sensing membrane is a elastic element of tension, compression and displacement with the change (for GP gauge transmitter, atmospheric pressure as applied in the low voltage side of the sensing membrane.). The AP absolute pressure transmitter, low voltage side always maintain a reference pressure. The sensing membrane Zui large displacement is 0.004 inches (0.1 mm), and the displacement is proportional to pressure. The capacitor plates on both sides of the diaphragm position detection sensor. The difference between the capacitance sensing diaphragm and capacitor plate is converted to the corresponding voltage or current, HART (high speed digital data highway addressable remote transmitter output signal).
          Third, widely used:
          For the measurement of gas, liquid and vapor pressure, and then turn it into a current signal output 4-20mADC. Can HART375, 475 hand operator to communicate with each other, setting and monitoring through them.
          Fourth, the main features:
          1, 5 years of continuous work without adjustment;
          2, the temperature effect is negligible;
          Influence of static pressure can be ignored;
          3, one-way impact: 100 thousand consecutive unidirectional overvoltage overvoltage after the experiment affect the amount of less than 0.03%;
          4, improve the self diagnosis function;
          5, small, lightweight (standard 3.9kg);
          6, static effects are neglected:
          When a static pressure (pressure), resonant beam deformation two shape, size and material identical to the same, so the frequency change is consistent, so the deviation automatically cleared (figure similar formula and temperature influence).
          7, excellent properties of unidirectional overvoltage:
          The liquid membrane and the membrane using corrugated box body processing technology of the original, so that the external pressure increases to a certain value, the film can fully contact with the body, silicone oil is transferred to the sensor pressure no longer increase with the increase of external force, so as to achieve the protective effect on sensor.
          Five, technical parameters:
          The 1. level measurement accuracy of 0.075%;
          2. calibration range from 0.25inH2O to 8310inH2O;
          3. flat film chip, 2-, 4-, and inch extend type diaphragm;
          4. kinds of filling liquid optional, can meet the requirements of different applications;
          5. clever and lightweight, easy installation and maintenance;
          6. liquid material: 316L stainless steel, Hastelloy, tantalum.
          Six, selection table:

          Model

          Product name

          3051L

          Flange mounted liquid level transmitter

          Code

          Pressure range (range /zui Small range)

          Two

          -250 to 250inH Two O/2.5H Two O (-62.2KPa to 62.2KPa/0.62KPa)

          Three

          -1000 to 1000inH Two O/10H Two O (-248KPa to 248KPa/2.5KPa)

          Four

          -8310 to 8310inH Two O/83.1H Two O (-2070KPa to 2070KPa/20.7KPa)

          Code

          output

          A

          4-20mA Based on a HART Digital signal protocol

          M

          Low power consumption, 1-5VDC Based on a HART Digital signal protocol ( 0.8-3.2VDC Output option code C2 )

          F

          FF Bus

          W

          PROFIBUS

          Code

          Diaphragm size

          Material Science

          Extended length

          Notes

          G0

          2in./DN 50

          316L SST

          Only the plane type

          Extension with diameterEighty The Conduit

          Size. Of Forty Pipe size,

          Please consult factory.

          H0

          2in./DN 50

          Hastelloy C-276

          Only the plane type

          J0

          2in./DN 50

          tantalum

          Only the plane type

          A0

          3in./DN 80

          316L SST

          Plane type

          A2

          3in./DN 80

          316L SST

          2in./50mm

          A4

          3in./DN 80

          316L SST

          4in./100mm

          A6

          3in./DN 80

          316L SST

          6in./150mm

          B0

          4in./DN 100

          316L SST

          Plane type

          B2

          4in./DN 100

          316L SST

          2in./50mm

          B4

          4in./DN 100

          316L SST

          4in./100mm

          B6

          4in./DN 100

          316L SST

          6in./150mm

          C0

          3in./DN 80

          Hastelloy C-276

          Plane type

          C2

          3in./DN 80

          Hastelloy C-276

          2in./50mm

          C4

          3in./DN 80

          Hastelloy C-276

          4in./100mm

          C6

          3in./DN 80

          Hastelloy C-276

          6in./150mm

          D0

          4in./DN 100

          Hastelloy C-276

          Plane type

          D2

          4in./DN 100

          Hastelloy C-276

          2in./50mm

          D4

          4in./DN 100

          Hastelloy C-276

          4in./100mm

          D6

          4in./DN 100

          Hastelloy C-276

          6in./150mm

          E0

          3in./DN 80

          tantalum

          Only the plane type

          F0

          4in./DN 100

          tantalum

          Only the plane type


          Code

          Installation flange size

          Rating

          Material Science

          Applicable to high voltage side of diaphragm size

          M

          2in.

          One hundred and fifty level

          carbon steel

          2 in./DN50

          A

          3in.

          One hundred and fifty level

          carbon steel

          3 in./DN80

          B

          4in.

          One hundred and fifty level

          carbon steel

          4 in./DN100

          N

          2in.

          Three hundredlevel

          carbon steel

          2 in./DN50

          C

          3in.

          Three hundredlevel

          carbon steel

          3 in./DN80

          D

          4in.

          Three hundredlevel

          carbon steel

          4 in./DN100

          P

          2in

          Six hundredlevel

          carbon steel

          2 in./DN50

          E

          3in.

          Six hundredlevel

          carbon steel

          3 in./DN80

          X

          2in.

          One hundred and fifty level

          SST

          2 in./DN50

          F

          3in.

          One hundred and fifty level

          SST

          3 in./DN80

          G

          4in.

          One hundred and fifty level

          SST

          4 in./DN100

          Y

          2in.

          Three hundredlevel

          SST

          2 in./DN50

          H

          3in.

          Three hundredlevel

          SST

          3 in./DN80

          J

          4in.

          Three hundredlevel

          SST

          4 in./DN100

          Z

          2in.

          Six hundredlevel

          SST

          2 in./DN50

          L

          3in.

          Six hundredlevel

          SST

          3 in./DN80

          Q

          DN 50

          PN 10-40

          carbon steel

          2 in./DN50

          R

          DN 80

          PN 40

          carbon steel

          3 in./DN80

          S

          DN 100

          PN 40

          carbon steel

          4 in./DN100

          V

          DN 100

          PN 10/16

          carbon steel

          4 in./DN100

          K

          DN 50

          PN 10-40

          SST

          2 in./DN50

          T

          DN 80

          PN 40

          SST

          3 in./DN80

          U

          DN 100

          PN 40

          SST

          4 in./DN100

          W

          DN 50

          PN 10/16

          SST

          4 in./DN100


          Code

          The process of oil filling -High pressure side

          Temperature limit

          A

          Syltherm XLT

          -75 to One hundred and fifty C (-102 to302 ~ F)

          C

          D.C.704 silicone oil

          Zero to Two hundred and five C (32 to401 degrees F)

          D

          D.C.200 silicone oil

          -45 to Two hundred and five C (-49 to401 degrees F)

          H

          Inert liquid

          -45 to One hundred and seventy-five C(-49 to 347 degrees F)

          G

          Glycerin and water

          -15 to Ninety-five C (5 to 203 degrees F)

          N

          Neobee M-200

          -15 to Two hundred and five C (5 to 401 degrees F)

          P

          Propylene glycol and water

          -15 to Ninety-five C (5 to 203 degrees F)


          Code

          option


          Header

          M (1)

          Linear meter, 0-100% scale

          M3 (1)

          The special calibration table, specify the range

          M4 (1)

          LCD Header, 0-100%

          M7 (1)

          LCD First, linear, special set


          Hazardous area certification

          E5

          The Canadian Standards Association (CSA) Flameproof certification

          I5 (2)

          Factory mutual (FM) Non flammable and safety certification

          K5

          Factory mutual (FM) Flameproof and intrinsically safe comprehensive certification

          C5 (3)

          Canada certification industry and Science ( Only Canada )

          C6 (2)

          I6 and E6 Combination, CSA Flameproof and intrinsically safe certification


          ( Requirement Zui High power supply voltage 42.4Vdc)

          K6

          CSA/CENELEC Flameproof and intrinsically safe certification

          EF (4)

          China NEPSI, GB Flameproof certification standard

          EF (2) (4)

          China NEPSI, GB Standard essential safety certification

          E4

          Japanese industrial standard (JIS) Flameproof certification

          E7

          The Standards Association of Australia (SAA) Flameproof certification

          E8

          CESI/CENELEC Flameproof certification

          I1 (2)

          BASEEFA The essence of security authentication

          I7 (2)

          The Standards Association of Australia (SAA) The essence of security authentication

          I8 (5)

          CESI/CENELEC The essence of security authentication

          N1 (2)

          BASEEFA N Type certification

          N7

          The Standards Association of Australia (SAA) Non flammable safety certification

          IC (2)

          SEV The essence of security authentication


          Other options

          W5

          copper O Ring type, used for vacuum occasions (non wetted parts)

          Q4

          Check data sheet

          Q8 (6)

          Material traceability, in accordance with EN 10204 3.1B

          L4

          316 SST Flange and bolt joints

          V1

          Inverting output

          V2

          4-20mV test signal

          V3

          20-100mV test signal

          Z1 (7)

          4- Line, 0-20mA output

          Z2 (7)

          4- Line, 0-16mA output

          Z3 (7)

          4- Line, 0-10mA output

          F_

          From table flush connection options in selecting a set of code

          Seven typical models:

          3051L2AG0RD21AAK5M5Q4
          3051L2AH0KD21AAM5
          3051L3AA0FD21AB