        2. Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
          0517-86918678
          Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
          Tel:0517-86918678
          Fax:0517-86918679
          Email:zhongweick@https://themugshotcompany.com
          Post Encoding:211600

          Explosion-proof thermal resistance

          6防(fang)爆型(xing)熱電(dian)阻(zu)(灋蘭式)01.png
          • 6防爆(bao)型熱電阻(灋蘭式(shi))01.png
          WZP-240 series Explosion-proof thermal resistance The structure, principle and assembly of thermal r…

          Description:

          Productoverview:

          WZP-240 series Explosion-proof thermal resistance The structure, principle and assembly of thermal resistance is basically the same, the difference is, flameproof or intrinsically safe explosion-proof junction box products (shell) special structure is adopted in the design, wiring box with high strength Aluminum Alloy die casting, and has sufficient internal space, wall thickness and mechanical strength, thermal stability of rubber seal the rings are in line with national standards. So, when the explosive mixed gases inside the enclosure when the explosion occurred, the internal pressure will not destroy the junction box, and the resulting heat is not the outward diffusion of detonation.

          Two, work principle:
          WZP-240 series Explosion-proof thermal resistance The gap explosion-proof junction box component design principle, with sufficient strength, all can produce a spark, arc and dangerous temperature components are sealed in a box cavity, when the cavity when the explosion occurred, the joint gap flameout and cooling, so that the explosion flame and temperature transmission to the outside of the cavity, thereby temperature measurement.
          Three, application:
          WZP-240 series Explosion-proof thermal resistance Usually, record and display instruments using instruments, electronic computing and other supporting. Direct measurement of hydrocarbons in the production site and other explosives -200 ~ C~500 ~ C range of liquid, steam and gas and solid surface temperature.
          Four, main features:
          1, various forms of explosion-proof, explosion-proof performance;
          2, large measuring range;
          3, high mechanical strength, good pressure resistance.
          4, a spring type temperature sensing element, good seismic performance;
          Five, technical parameters:
          Product executive standard
          IEC751
          JB/T18622-1997
          JB/T8623-1997
          JB/T5518-91
          Insulation resistance at room temperature
          Heat resistance at ambient temperature is 15 to 35 DEG C, relative humidity is less than 80%, the test voltage is 10 - 100V (DC) >100M. The insulation resistance between electrode and outer tube.

          Six, installation method:
          1, first of all should measure the good thermal resistance thread thread or flange size, supporting flange or thread processing base.
          2, according to the size of the base flange or threaded hole in the pipe, to be measured.
          3, the flange or the screw tooth of the welding. The flange or thread is inserted has opened hole in the flange or threaded seat base and pipeline measured welding.
          4, the screw base thermal resistance with bolts or threaded in has been welded.
          5, in accordance with the wiring diagram of the terminal box thermal resistance grounding line, and the display instrument is connected on the dial corresponding. Connection box can not contact with the wall of the measured medium pipeline, ensure the junction box temperature not exceeding 100 DEG C. Outlet hole junction box should prevent due to poor sealing water vapor, dust deposition caused by short circuit terminal.

          Seven, measurement range and tolerance:

          Model

          Graduation

          The temperature range of C DEG

          Precision grade

          Tolerance

          WZP240

          Pt100

          -200-+500

          A

          (0.15+0.002 + LTL)

          WZC240

          Pt100

          -200-+500

          B

          (0.30+0.005ltl).

          Eight, selection table:

          Code

          WZ - - - - - - - - - - - - - / - armored thermal resistance

          W

          Temperature meter (Zhongwei control)


          Code


          Z

          Heat resistance


          Code

          The temperature measuring element

          P

          Pt100 Pt1000 (the order required)

          C

          Cu50


          Code


          K

          Armoured type (assembled the symbol)


          Code



          Single

          Two

          Double branch


          Code

          Installation assembly (armoured)

          Zero

          No protection tube

          One

          No fixed device

          Two

          Fixed thread

          Three

          Movable flange

          Four

          Fixed flange

          Five

          90 degree angle flange

          Six

          Fixed thread taper

          Code

          Installation of armor type

          One

          No fixed device

          Two

          The fixed clip sleeve thread

          Three

          Flecible thread

          Four

          The fixed clip sleeve flange

          Five

          The movable ferrule flange


          Code

          Connection box

          Zero

          Simple type

          One

          Ordinary type

          Two

          Splash proof (waterproof type substitution)

          Three

          Waterproof type

          Four

          Explosion proof type

          Six

          Socket type

          Seven

          With the connecting wire type


          Code

          Armoured armoured body diameter

          Three

          Phi 3mm

          Four

          Phi 4mm

          Five

          Phi 5mm

          Six

          Phi 6mm

          Eight

          Phi 8mm

          Code

          The diameter of the outer protection tube assembly (full armor)

          Zero

          Phi 16mm

          One

          Phi 12mm

          Heat resistance A By ordering protocol.

          Note: the connector form, convenient installation, suitable for measuring -200-450 Liquid, gas and solid surface temperature range.

          The design and selection of notes:
          1, model;
          2, division no.;
          3, precision grade;
          4, fixed form;
          5, the length or depth of insertion.
          Customer service service commitment:
          1, my company sold Zhongwei Thermal resistance series The product within twelve months of quality problems, responsible for free maintenance.
          2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
          3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
          4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
          5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.