          Roof type thermocouple

          8鑪頂(ding)熱電偶(ou)1.jpg
          • 8鑪(lu)頂熱電(dian)偶1.jpg
          WRN-0313T series Roof type thermocouple A temperature measuring device for power plant boiler roof a…

          Description:

          Productoverview:
          WRN-0313T series Roof type thermocouple A temperature measuring device for power plant boiler roof and other occasions to long distance, high temperature. It is composed of two different electrode conductor material composed of the temperature difference between measuring terminal end with the reference will produce thermal potential, the working instrument will display the temperature value corresponding to the thermal potential. Due to the shape of crown thermocouples often very different, but their basic structures are roughly the same, often by the power pole, the main part of the insulation protection tube and sleeve connection box, and usually display instrument, recording instrument and supporting the use of electronic regulator.
          Two, Working principle:
          WRN-0313T series Roof type thermocouple Two different components of the conductor (called thermocouple wire or thermal electrode) is connected to the two ends of the synthetic circuit, when the junction temperature at the same time, in the loop will produce electromotive force, this phenomenon is called the thermoelectric effect, and this is called thermal electromotive force emf.
          A thermocouple is used to measure temperature of this principle, which is directly used for measuring the temperature of a medium called the working end (also known as the measuring end), the other end is called the cold end (also known as the end of the cold end compensation); and display instrument or meter display instrument connection, will point out that the thermoelectric potential generated by thermocouple.
          Three, Applications:
          WRN-0313T series Roof type thermocouple Suitable for a power plant boiler roof and other required long distance, high pressure temperature measurement occasions.

          Four, main features:

          1, simple assembly, convenient replacement;

          2, a spring type temperature sensing element, good seismic performance;

          3, large measuring range.

          Five, Technical parameters:
          1, electrical outlet: M16 * 1.5;
          2, size: M16 * 1.5;
          3, protection grade: lP65.

          Six, installation requirements:

          The thermocouple installation should pay attention to details; several thermocouples were installed in use; for the temperature measurement is accurate, safe and convenient maintenance, and does not affect the equipment operation and production operation. To meet the following requirements, in the choice of the thermocouple installation position and insert depth should pay attention to the following 2 points:
          1, with a protective casing thermocouple heat transfer and heat loss, in order to reduce the measurement error, the thermocouple should have sufficient depth of insertion.
          A, when measuring the original insertion depth is more than 1m, should be installed vertically, or installing supporting frame and a protective sleeve.
          B, if you need to measure the flue gas temperature is, while the flue diameter is 1000mm, the depth of the thermocouple insert 500mm.
          C, for the temperature measurement of fluid pipe center thermocouple, generally the measuring end is inserted into the pipe center (vertical or inclined installation). If the measured fluid pipe diameter is 100 mm, the depth of the thermocouple insert should choose 50~100 mm (should take into account the size installation base or flange).
          D, for temperature measurement of high temperature and high pressure and high speed fluid (such as main steam temperature), in order to reduce resistance to the fluid and prevent the protective sleeve to protect the casing fracture under the influence of the fluid, can take the protection tube or shallow inserted by thermal sleeve type thermocouple. Shallow inserted thermocouple protection tube type, which is inserted into the main steam pipeline the depth should be less than 75mm; thermal sleeve type thermocouple standard insert depth 100mm.
          2, in order to make the measurement end of thermocouple and measured with sufficient heat exchange medium, should choose a reasonable measuring position, to avoid the valve, elbow and piping and equipment installation thermocouple near the corner.

          Seven, Specification description:

          ModelGraduationThe measuring range of CNominal pressureCurrent SpeedSpecification (mm)
          LL

          WRN-0313T

          WRN2-0313T

          K0-800Less than 30MPaLess than 100m/s

          One thousand

          Two thousand

          Three thousand

          Four thousand

          Five thousand

          Six thousand

          Eight thousand

          Ten thousand

          Fifteen thousand

          Twenty thousand

          Twenty-five thousand

          Fifty

          One hundred

          One hundred and fifty

           

          WREK-0313T

          WREK2-0313T

          E0-600

          WRNK-0913T

          WRNK2-0913T

          K0-800

          WREK-0913T

          WREK2-0913T

          E0-600

          Note: 1, Thermocouple I according to the ordering protocol;
          2, the protective tube is made of 1Cr18Ni9Ti material, the order according to the agreement.
          Eight, Design selection and ordering information:
          1, model;
          2, division no.;
          3, precision grade;
          4, protection tube material and form;
          5, the length or depth of insertion. 
          Customer service service commitment:
          1, my company sold Zhongwei Thermocouple series The product within twelve months of quality problems, responsible for free maintenance.
          2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
          3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
          4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
          5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, 48 hours outside users arrive at the scene.