          Type Selection Instructions for Micro Flow Metal Tube Rotor Flowmeter
          • File Name:Type Selection Instructions for Micro Flow Metal Tube Rotor Flowmeter
          • Add Time:2019-04-12 10:30:20
          • Document Size:
          • Recommendation:
          • Immediately Download:
          Download Instructions:

          Productoverview:
          ZW-LZZW series of micro flow of metal tube rotameter has the characteristics of strong, stable, reliable and wide application range, can be used for measuring gas and liquid.All metal design to ensure its high pressure, high temperature stability, can withstand extreme environmental conditions.The position of the magnetic induction transmitted to an analog indicator displays the measured values.Without power.
          Two, the structure and principle of measurement:
          1, structure:
          ZW-LZZW series of micro flow of metal tube rotameter is mainly composed of three parts:
          A (Intelligent indicator, indicator, local indicator);
          B, float;
          C, a conical measuring chamber.
          2, the principle of measurement:
          On the lower end of the measured medium from the measuring tube through a conical float generating differential pressure form the upward force, when the float on the lift is greater than immersion float in the fluid weight, the float will rise, annulus area increases, the annulus fluid velocity decreased immediately, float on the lower pressure reduced, to float up with the decrease in stress, until the lift is equal to the weight of the float when immersed in a fluid, the float will stabilize at a certain height.The float position that corresponds to the size of the measured medium flow.A built-in magnet, the float with the medium moves up and down, with the movement of the float magnetic field changes.
          A, for in situ, by rotary magnetic float and the local indicator in the inner magnetic coupling, rotate, and drives the pointer, through the dial indicates the size of the flow.
          B, the intelligent, by a solid state magnetic sensor intelligent indicator in the magnetic field will change into electrical signal output by A/D transform, D/A microprocessor, LCD liquid crystal display to show the size and cumulative flow flow.
          Three, widely used:
          ZW-LZZW series of micro flow of metal tube rotameter is widely used in petroleum, chemical, power, pharmaceutical, food, water treatment, etc..The complex, harsh environmental conditions, the flow measurement process and various medium conditions in.
          Fourth, the main features:
          1, all metal structure, strong stability, suitable for high temperature and high pressure, strong corrosive medium.
          2, using the isolation design, imported relay output, to ensure reliable operation.
          3, in all sectors of the measurement of gas and liquid, the measuring part can be using different materials to adapt to various medium conditions.
          4, the vertical and horizontal installation, more suitable for different occasions.
          5, the magnetic coupling structure to ensure data transmission, more stable signal.
          6, magnetic filter, with thermal insulation or jacket design.
          7, the vertical and horizontal installation, more suitable for different occasions.
          8, can be used in flammable and explosive occasions.
          Five, technical parameters:
          1. measuring range: water (20 C) (0.3 ~ 100) L/h; air (20 degrees 101325Pa) (1.2 ~ 3400) L/h;
          2. range: 10:1;
          3. accuracy level: 4
          Maximum working pressure: 4. 2.5MPa (according to the need of increase)
          5. medium temperature: -80 ~ +150 C
          6. environment temperature: -25 ~ +65 C
          7. connection: 1/4 "NPT thread or phi 6 (phi 8) sleeve connection / vertical connection according to the level of user requirements
          8. limit alarm: 1~2 alarm switch (optional)
          9. dimensions: overall size: 110mm; installation center distance: 90mm;
          Sixth, product maintenance:
          1, in the process of long-term use, the pipeline inevitably there will be ferromagnetic impurity adsorption on the float, it will float stuck or affect the measurement accuracy, from time to time to clean the sensor float; if the installation of magnetic filters should be cleaned regularly.
          2, instrument indicator equipped with electronic components, instrument wiring or demolition of housing, to housing screws, must ensure sealing, prevent impurities, or other material into the water, and also to ensure reliable earthing of the meter casing.
          3, instrument installation, on first use, should pay attention to:
          When the valve is opened to avoid the formation of pressure shock makes the float slamming limiting device, causing damage to the instrument, slowly open the valve!
          The measurement of gas meter is equipped with gas damper, to minimize the shock; to ensure the stability of the float, a throttle valve can be installed in the instrument export.
          4, for the remote type instrument, we must first ensure that the instrument wiring correctly, keeps power; for dangerous situations, must choose the explosion-proof, and the installation and use of proof required by the.
          Seven, the installation should follow the following steps:
          1, before installing the instrument to process piping, should remove all installed and checked for any transport damage;
          2, in order to prevent in transit, with a rubber band fixed pointer indicator, indicator should open the left cover it gently removed before connection, do not change the pointer position;
          3, open the indicator of the right cover, cable through the cable introducing device, according to the wiring diagram wiring rotation transmitter, pressure screw nut, the cable is fixed, and then tighten the fastening screws around the cover, the indicator of waterproof and dustproof;
          4, upstream and downstream piping and instrument instrument should be the same caliber, flange or threaded connection should be matched with the flange and screw instrument, instrument upstream straight pipe length should be 5 times the nominal diameter of the instrument, the downstream straight pipe length not less than H2 250mm;
          5, the instrument measuring mechanism is magnetic transfer, so in order to ensure the performance of rotameter installed around the sensor, at least 100mm, the existence of ferromagnetic material is not allowed;
          Before installation, 6 meter pipeline sweeping shall be carried out, to prevent the retention of ferromagnetic material in the pipeline is attached to the instrument, the instrument performance, or even damage the instrument. If unavoidable, should be installed at the entrance of the magnetic filter instrument;
          7, the measurement of gas meter is calibrated in special pressure, if the gas meter in the outlet directly discharged into the atmosphere, will produce a pressure drop in the float, and lead to data distortion.If this is the working conditions, should install a valve in the instrument exports, so that the required flow value is set, when the float to maintain calibration pressure, gas expansion in valve;
          The installation form 8, instrument installation for vertical and horizontal installation, if it is installed in a vertical straight form, should ensure that the instrument is better than 1%; if the level of installation form should ensure that the level of less than 1% meters;
          9, installed in the pipeline in the instrument should not be subject to stresses, the instrument should be a proper entrance and exit pipe support, can make the instrument in the minimum stress state;
          10, product and computer related to calibration and other operations, must be in a safe place.
          Eight, installation notes:
          In 1, before the first installation flowmeter in the pipeline, dirt, impurities such as welding blowing clean, if the liquid contained solid impurities, should the corresponding filter is installed between the valve and the straight pipe.
          2, shielding and grounding system: in order to ensure ideal electromagnetic compatibility, shielding and grounding is very important, especially the bus cable, cable as far as possible to make continuous shielding.
          3, the safety zone, according to the requirements of conventional cable grounding as much as possible.
          4, in dangerous places, to ensure that the whole range of bus safe places and dangerous enough, all the potential, in this case, multiple ground is very superior.

          Nine, choose the flow table:

          Decay path

          Common path

          measuring range

          The maximum pressure loss

          DN (mm)

          DN (mm)

          The air (m3/h)

          Water (L/h)

          The air (KPa)

          Water (KPa)

          Fifteen

          Fifteen

          0.05-0.5

          1.6-16

          Seven

          Six point four

          0.07-0.7

          2.5-25

          Seven point one

          Six point five

          0.11-1.1

          4.0-40

          Seven point two

          Six point five

          0.18-1.8

          6.0-60

          Seven point three

          Six point six

          0.28-2.8

          10-100

          Seven point five

          Six point six

          0.40-4.0

          16-160

          Eight

          Six point eight

          0.70-7.0

          25-250

          Ten point eight

          Seven point two

          1.00-10

          40-400

          Ten

          Eight point six

          1.60-16

          60-600

          Fourteen

          Eleven point one

          Twenty-five


          80-800


          Fourteen

          Twenty-five

          3.00-30

          100-1000

          Seven point seven

          Seven

          4.50-45

          160-1600

          Eight point eight

          Eight

          7.00-70

          250-2500

          Twelve

          Ten point eight

          11-110

          400-4000

          Nineteen

          Fifteen point eight

          Fifty


          500-5000


          Sixteen point two

          Fifty

          18-180

          600-6000

          Eight point six

          Eight point one

          25-250

          1000-10000

          Ten point four

          Eleven

          Eighty

          40-400

          1600-16000

          Twelve point six

          Seventeen

          Eighty

          50-500

          2000-20000

          Fifteen point five

          Six point three

          One hundred

          75-750

          2500-25000

          Seventeen Point Two

          Eight point one

          One hundred

          100-1000

          4000-40000


          Nine point five

          One hundred and twenty-five

          160-1600

          6000-60000


          Ten

          One hundred and twenty-five

          250-2500

          8000-80000


          Sixteen

          One hundred and fifty


          10000-100000


          Twenty


          300-3000

          12-120m3/h


          Twenty


          400-4000

          15-150m3/h


          Twenty-five

          Ten, selection table:

          Specification code

          Explain

          The name of the factory

          ZW

          Zhongwei control

          Instrument types

          LZZW

          The micro flow of metal tube flowmeter

          structural style

          A

          In the next

          B

          Progress under the

          C

          Side measure

          D

          The bottom side

          R

          Right into the left out

          L

          The left into the right

          K

          Clamp connection (sanitary polishing tube)

          W

          Threaded connection

          Size code

          - XXX

          DN15 said: 15 cases

          The measuring tube material

          R1

          1Cr18Ni9Ti, 304

          R0

          0cr18Ni12M02Ti, 316

          RL

          316L

          RP

          PTFE (PTFE)

          Ni

          Hastelloy (Hastelloy C)

          Ti

          TitHXium (Tai Hejin)

          Media type

          L

          liquid

          G

          Gas

          working temperature

          H1

          - 40 -100 OC

          H2

          - 80 -250 OC

          Rated pressure

          One point six

          1.6MPa

          Four

          4.0MPa

          Sixteen

          16MPa

          Twenty-five

          25MPa

          Additional structure

          O

          nothing

          Z

          Damping type

          T

          Jacket

          H

          High temperature type

          Y

          High pressure type

          Form indicator

          M1

          Local indication

          M2

          Intelligent

          M3

          Intelligent (explosion)

          The output signal in the communication

          N

          nothing

          A

          4-20mA

          H

          4-20mA+Hart

          Alarm controller

          K1

          The upper limit alarm

          K2

          Alarm

          K12

          The upper and lower limit alarm

          Explosion proof type

          E1

          Intrinsically safe EXiaCT5 square casing

          E2

          Flameproof shell EXiibt4 Park

          Power supply

          Zero

          24VDC (optional)

          Two

          220VAC

          Three

          The 3.6 volt lithium battery