        2. Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.

          Glass tube rotameter

          18玻瓈筦(guan)轉(zhuan)子(zi)流量(liang)計01.jpg
          18玻瓈(li)筦轉子流(liu)量計(ji)03.jpg
          18玻瓈筦(guan)轉(zhuan)子流(liu)量計(ji)02.jpg
          • 18玻(bo)瓈(li)筦(guan)轉(zhuan)子流量(liang)計(ji)01.jpg
          • 18玻(bo)瓈筦(guan)轉(zhuan)子流(liu)量計(ji)03.jpg
          • 18玻(bo)瓈(li)筦(guan)轉子流(liu)量(liang)計(ji)02.jpg
          ZW-LZB/LZJ series Glass tube rotameter According to its purpose and scope can be divided into: ordin…

          Description:

          Productoverview:

          ZW-LZB/LZJ series Glass tube rotameter According to its purpose and scope can be divided into: ordinary type, ribbed vascular type, small flow and low profile type, corrosion type, laboratory type, insulation type, alarm type and high pressure type eight series. According to the formulation of national instrument series, regardless of which Zui series, ranging from 1 to 100 mm in diameter and a total of 12 numbers, can measure the flow range: liquid (water) 0.1 ml / min to 40 cubic meters / hour, gas (air) 1 ml / min to 1000 cubic meters / hour. For environmental protection equipment of the glass rotameter is generally not more than 10 mm diameter, the flow measurement of small flow range.

          Two, work principle:

          ZW-LZB/LZJ series of glass tube rotameter is mainly composed of a bottom enlarged glass tube and a cone with the magnitude of fluid flow moves up and down the stainless steel float. The fluid flows through the cone bottom tube, buoyancy A fluid kinetic energy generated on the float lift S and fluid to float up, when the lift and buoyancy of A and S is equal to the gravity float G, float in the balance, stable at a certain height position, cone scale on the tube indicates that the fluid flow value.

          ZW-LZB- (F) for smooth wall cone tube flowmeter tube diameter meter above DN15, the float remained stable through the movement, the guide rod; ZW-LZJ- (F) three meter cone tube guide rib, the float remained stable. Through the meter diameter of DN10 or less connected by a hose, equipped with needle flow control valve; path DN15 flowmeter with flange connection.

          Three, application:

          ZW-LZB/LZJ series of glass tube rotameter is mainly used in chemical, petroleum, light industry, medicine, chemical fertilizer, chemical, food, dyestuff, environmental protection and scientific research departments, used to measure single-phase non pulsating (liquid or gas) fluid flow.

          Anticorrosion type is mainly used for the detection of corrosive liquid and gas medium flow, such as acid and alkali, oxidant, strong oxidizing acid, organic solvents and other corrosive gas or liquid medium flow detection.

          Four, main features:

          1, small pressure loss. In the process of using, can be fully utilized, without a lot of effort too much, all the pressure can be fully used, there will be no loss.

          2, reliable performance. Glass rotor flowmeter in operation, frequent failure will not ensure good operation. When people are in the process of using, don't worry about running for it. Good performance, high reliability, can be assured use.

          3, simple structure, convenient installation and use. The structure of the glass rotameter is simple, the installation is very convenient, can be installed in a short period of time.

          Fifth, technical parameters:

          1, size: DN2 ~ 100mm;

          2, measuring range: water (20 C): 1L/h ~ 100m3/h, gas (101325Pa, 20 C): 16L/h ~ 3000m3/h;

          3, the range ratio: 10: 1;

          4, precision grade: grade 1.5, grade 2.5, grade 4;

          5, nominal pressure: DN4 ~ 10 1.0MPa, 50 0.6MPa, DN15 ~ DN80 ~ 100 0.4MPa;

          6, working temperature: less than or equal to 120 DEG c;

          7, connection: hose, metal pipe, flange (GB/T9119-2000);

          8, material: flange, float, a guide rod, a supporting plate and bolts are made of stainless steel 304 (1Cr18Ni9Ti), type LZB-B.

          Note: the wetted materials for use in 316, is a model for the LZB-Bo, can be customized.

          For stainless steel PTFE is type LZB-BF (or BoF), can be customized.

          Six, selection method:

          1, measurement. Measuring the media type, size, pressure and chemical properties. Such as liquid and gas medium, the corrosive medium should choose corrosion resistance meter.

          2, the performance of flowmeter. The above conditions are identified in general, if the price is no big change, may be preferred needle valve is arranged on the upper part of the large circulation flow meter; hole, direct flow scale; simple structure; small exterior dimensions etc.. Such as small flow range, you can choose to use the ball float type, because of its measurement stability, not easy dust, high precision, good interchangeability.

          The price of 3, according to the. Generally speaking, the high price of high precision. According to the measurement instruments such as precision grade, only through the medium of control measure, the operation adjustment, after always stabilize the throughput, so the accuracy is minor.

          Seven, matters needing attention:

          1, don't put the front cover removed, because the glass tube easy blasting, shell to protect.

          2, when used in winter, should pay attention to keep warm, if the night is not used, the residual liquid in the flow discharged, so as not to freeze broken glass tube.

          3, to the pipeline installation, first look at the downstream pipeline is in a straight line. If not in a straight line, will not only affect the measuring accuracy of the instrument, but also will damage the flowmeter.

          4, when the valve is opened, will slowly open, if the estimated flow to floating rotor, and the rotor does not move up, immediately stop valve, tap the pipeline, so that the rotor can slowly rise.

          5, first observed within the flow tube is intact, glass tube is easy to damage; second is to remove the rotor fixture, gently slide backward to see whether the rotor freely up and down. If not free to slide, vibration plate gently. If we can not slide, would need professional solutions.

          Eight, specifications and measuring range:

          1, ordinary type:

          LZB-2

          LZB-3

          Model

          LZB-4

          LZB-6

          LZB-10

          Phi 2

          Phi 3

          Nominal diameter mm

          Phi 4

          Phi 6

          Phi 10

          Less than or equal to 1

          Less than or equal to 1

          The working pressure of MPa

          Less than or equal to 1

          Less than or equal to 1

          Less than or equal to 1

          + 4

          + 4

          Basic error limit%

          + 4

          + 2.5

          + 2.5

          1:10

          1:10

          The scope of

          1:10

          1:10

          1:10

          0.4~4

          2.5~25

          liquid
          Ml/min

          measuring range

          liquid
          L/h

          1~10

          2.5~25

          6~60

          0.6~6

          4~40

          1.6~16

          4~40

          10~100

          1~10

          6~60

          2.5~25

          6~60

          16~160

          1.6~16

          10~100

          6~60

          40~400

          Gas
          Ml/min

          Gas
          L/h

          16~160

          40~400

          100~1000

          10~100

          60~600

          16~160

          100~1000

          25~250

          60~600

          160~1600

          25~250

          160~1600

          40~400

          100~1000

          250~2500

          2, ordinary type:

          Model

          LZB-15

          LZB-25

          LZB-40

          LZB-50

          LZB-80

          LZB-100

          Nominal diameter

          Phi 15

          Phi 25

          Phi 40

          Phi 50

          Phi 80

          Phi 100

          Ratio measurement

          1:10

          1:10

          1:10

          1:10

          1:5 1:10

          1:5

          Working pressure

          Less than or equal to 0.6

          Less than or equal to 0.6

          Less than or equal to 0.6

          Less than or equal to 0.6

          Less than 0.4

          Less than 0.4

          Precision grade

          Two point five

          One point five

          One point five

          One point five

          One point five

          One point five

          Flow range

          liquid

          (m3/h)

          16-160 (L/h)

          40-400 (L/h)

          0.16-1.6

          0.4-4.0

          1-10

          5-25

          25-250 (L/h)

          60-600 (L/h)

          0.25-2.5

          0.6-6.0

          1.6-16

          8-40

          40-400 (L/h)

          100-1000 (L/h)





          Gas

          (NM3/h)

          0.25-2.5

          1-10

          4-40

          10-100

          50-250

          120-600

          0.4-4.0

          1.6-16

          6-66

          16-160

          80-400

          200-1000

          0.6-6.0

          2.5-25





          3, corrosion resistance:

          Model

          LZB-15F

          LZB-25F

          LZB-40F

          LZB-50F

          LZB-80F

          LZB-100F

          Nominal diameter

          Phi 15

          Phi 25

          Phi 40

          Phi 50

          Phi 80

          Phi 100

          Ratio measurement

          1:10

          1:10

          1:10

          1:10

          1:5 1:10

          1:5

          Working pressure

          Less than or equal to 0.6

          Less than or equal to 0.6

          Less than or equal to 0.6

          Less than or equal to 0.4

          Less than or equal to 0.4

          Less than or equal to 0.4

          Precision grade

          Four

          Two point five

          Two point five

          Two point five

          Two point five

          Two point five

          Flow range

          liquid

          (m3/h)

          16-160 (L/h)

          40-400 (L/h)

          0.16-1.6

          0.4-4.0

          1-10

          5-25

          25-250 (L/h)

          60-600 (L/h)

          0.25-2.5

          0.6-6.0

          1.6-16

          8-40

          40-400 (L/h)

          100-1000 (L/h)





          Gas

          (NM3/h)

          0.25-2.5

          1-10

          4.0-40

          10-100

          50-250

          120-600

          0.4-4.0

          1.6-16

          6.0-66

          16-160

          80-400

          200-1000

          0.6-6.0

          2.5-25





          4, LZB-S:

          Model

          LZB-15S

          LZB-25S

          LZB-50S

          LZB-80S

          Nominal diameter mm

          Phi 15

          Phi 25

          Phi 50

          Phi 80

          The working pressure of MPa

          Less than or equal to 0.6

          Less than or equal to 0.6

          Less than or equal to 0.6

          Less than 0.4

          The basic error indication limit%

          + 2.5

          + 2.5

          + 2.5

          + 2.5

          measuring range

          Liquid L/h

          4~90

          70~700

          450~7000

          7000~30000

          Stainless steel
          Flanges, a float, a guide rod, a supporting plate and bolts are made of stainless steel 304 (1Cr18Ni9Ti), type ZW-LZB- (B).
          Wetted materials such as the need to use 316, then type ZW-LZB- (Bo), can be customized.
          For stainless steel PTFE is type ZW-LZB- (BF) (or BoF), can be customized.
          PTFE type
          Base, float, needle with polytetrafluoroethylene (PTTFE). Support plate and screws made of stainless steel.

          Nine, appearance and installation dimensions:

          Table 1,

          Path

          The size (mm)

          A

          B

          C

          D

          E

          Two

          One hundred and ten

          One hundred and thirty-two

          One hundred and fifty

          M8 * 1

          31 x 26 (front)

          Three

          One hundred and ten

          One hundred and thirty-two

          One hundred and fifty

          M8 * 1

          31 x 26 (front)

          Four

          One hundred and seventy

          Two hundred and eight

          Two hundred and thirty-eight

          Phi 11

          40 x 34 (front)

          Six

          One hundred and seventy

          Two hundred and eight

          Two hundred and thirty-eight

          Phi 11

          40 x 34 (front)

          Ten

          One hundred and seventy

          Two hundred and eight

          Two hundred and thirty-eight

          Phi 11

          40 x 34 (front)

          Table two:

          Diameter (mm)

          The size (mm)

          A

          B

          C

          D

          E

          Fifteen

          Phi 95

          Phi 65

          Four hundred and seventy

          Phi 15

          With the diameter of 14 4-

          Twenty-five

          Phi 105

          Phi 78

          Four hundred and seventy

          Phi 25

          With the diameter of 14 4-

          Forty

          Phi 145

          Phi 110

          Five hundred and seventy

          Phi 40

          With the diameter of 18 4-

          Fifty

          Phi 160

          Phi 125

          Five hundred and seventy

          Phi 50

          With the diameter of 18 4-

          Eighty

          Phi 185

          Phi 150

          Six hundred and sixty

          Phi 80

          With the diameter of 18 4-

          One hundred

          Phi 205

          Phi 170

          Six hundred and sixty

          Phi 100

          With the diameter of 18 4-

          10, encoding selection:

          ZW-LZB

          -

          caliber

          function

          Description (Zhongwei control)



          DN2-100


          caliber


          No label

          Ordinary type

          F

          Corrosion proof type, PTFE base (for DN2~DN10) or carbon steel flange lining PTFE

          B

          All stainless steel material: 304 stainless steel

          B0

          All stainless steel material: 316 stainless steel

          F/B (B0)

          Type: stainless steel corrosion-resistant stainless steel flange (304 or 316) lined with PTFE (for DN15~DN100)

          ZW-LZB

          -

          .

          .

          Glass tube flowmeter

          Common type: mainly applicable to non corrosive medium measurement;

          Corrosion proof type: mainly suitable for corrosive medium measurement;

          All stainless steel type: mainly applicable to sanitary and weak corrosive medium measurement, can anti corrosive gas environment for use in;

          Stainless steel corrosion proof type: mainly suitable for corrosive media measurement, can anti corrosive gas environment in use.

          Eleven, ordering:

          1, according to the measurement of the fluid is a gas or liquid, the correct selection of ZW-LZB rotor flowmeter.

          2, the measured fluid is non corrosive with ordinary type, corrosive resistant type selection.

          3, please specify when ordering the names, the measured flow rate, pipe diameter and pressure, temperature, density, viscosity, etc.. According to the user's density of correction, making special flow gauge.

          4, according to the measurement range and measured fluid applications such as choosing the suitable type of the specifications. As the special requirements of the flowmeter, or call the sales department, and company.

          Customer service service commitment:

          1, our series of flowmeter series product quality problems within 12 months, responsible for free maintenance.

          2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.

          3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.

          4, the warranty period after the product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.

          5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.


          Browse:
          Return To The Top

          分亯到:

          SiFzb

            • <b id="6X5oBEp"></b>

                1. <legend></legend>
                  <tr id="6X5oBEp"></tr>