        2. Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.

          Corrosion proof metal tube rotameter

          18金屬(shu)筦(guan)轉子流(liu)量(liang)計(ji)(防(fang)腐型).jpg
          • 18金(jin)屬筦轉(zhuan)子流(liu)量計(ji)(防(fang)腐型).jpg
          ZW-LZ series Corrosion proof metal tube rotameter The measuring tube indicator independent concept d…

          Description:

          Productoverview:

          ZW-LZ series Corrosion proof metal tube rotameter The measuring tube indicator independent concept design, can choose stainless steel, Hastelloy, titanium, PTFE material measurement system, low pressure loss. The magnetic coupling flowmeter structure to ensure data transmission, more stable signal. Insulation or heating jacket, the vertical and horizontal installation, more suitable for different occasions. Suitable for small diameter and low flow velocity measurement for the medium, the straight pipe is not high. Wide flow ratio 10:1; double large LCD display, optional field instantaneous / total flow rate display, with backlight; all metal structure, suitable for high temperature, high pressure and strong corrosive medium; can be used in flammable and explosive occasions; selection of AC power supply, battery, two-wire; with data recovery, data backup and power down protection.

          Second, working principle:

          ZW-LZ series of anticorrosive metal tube rotameter is the medium to be measured through a conical measuring tube float from upper and lower ends of the differential pressure generated form the upward force, when the float was immersed in a fluid on the lift is greater than the weight of the float, the float will rise, annulus area increases, the annulus fluid velocity decreased immediately float the lower end of the differential pressure is reduced, to float upward force also decreases with, until the lift is equal to the weight of the float when immersed in a fluid, the float will stabilize at a certain height. The float position that corresponds to the size of the measured medium flow. A built-in magnet, the float with the medium moves up and down, with the movement of the float magnetic field changes.

          A, for in situ, by rotary magnetic float and the local indicator in the inner magnetic coupling, rotate, and drives the pointer, through the dial indicates the size of the flow.

          B, the intelligent, by a solid state magnetic sensor intelligent indicator in the magnetic field will change into electrical signal output by A/D transform, D/A microprocessor, LCD liquid crystal display to show the size and cumulative flow flow.

          Third, application:

          ZW-LZ series of anticorrosive metal tube rotameter is suitable for the measurement of liquid, gas.Widely used in petroleum, chemical, power, pharmaceutical, food, water treatment, etc.. The complex, harsh environmental conditions, the flow measurement process and various medium conditions in.

          Four, main features:

          1 of all metal structure design, strong, simple, high pressure resistance, high temperature resistance, corrosion resistance, long service life;

          2 short stroke, high 250mm, convenient installation;

          3 mechanical pointer instructions LCD liquid crystal display instantaneous flow, instantaneous flow, cumulative flow;

          4 intelligent indicator, using foreign Zui new signal processing chip, modular design, no hysteresis;

          The 5 is data recovery, data backup, power down protection and fault self diagnosis function;

          6 HART type indicator, two-wire 24VDC power supply, 4-20mA standard current signal output of HART protocol stack;

          7 through HART communication manipulator configuration and parameters can be adjusted;

          8 and PC serial connection, through the Windows program, to achieve on-site calibration of the instrument;

          9 can be used in flammable and explosive occasions;

          10 vertical and horizontal, upper lower, bottom side, side into the side such as the installation of a variety of forms, flange or threaded connection.

          Five, technical parameters:

          Measuring range: water (20 C) 1-200000 L / h;

          The air (at 20 0.1013MPa) 0.034000m3 / h;

          See flow table, special traffic can be customized;

          Range: standard type 10:1 special type 20:1;

          Precision: standard type 1.5 special type 1;

          Pressure rating: Standard Type: 4.0MPa DN80-DN200 1.6MPa DN15DN50;

          Special type: 25MPa DN80-DN200 16MPa DN15DN50;

          The pressure rating of jacket for 1.6MPa;

          Special type in the selection and ordering should negotiate with the factory;

          Pressure loss: 7kPa-70kPa;

          Medium temperature: Standard Type: 80 c c c c: PTFE:0 85 -200;

          High temperature type: Zui up to 400 DEG c;

          Medium viscosity: DN15: <5mPa.s (F15.1-F15.3);

          <30mPa.s (F15.4-F15.8);

          DN25: <250mPFa.s;

          DN50-DN150: <300mPa.s;

          Ambient temperature: - 30 DEG C C +85 type liquid crystal;

          Pointer type 40 C C +120;

          Connection type: Standard Type: DIN2501 standard flange;

          Special type: specified by the user in any standard flange or thread;

          Cable interface: M20 * 1.5;

          Power supply: standard type 24VDC (10.8VDC36VDC) 4 - 20mA with two-wire system;

          AC: 85265VAC 50HZ.

          Six, installation requirements.

          Remove the filler, 1 meter box after check, the meter should be installed vertically in the pipeline without vibration, such as to the level of the installation, the order should be additional instructions. The angle between the line and the plumb line flowmeter center should not exceed 5 degrees.

          In 2, the newly installed pipeline flow meter should be installed before the new pipeline clean metal pipe, if the measured medium containing impurity particles or bubbles, you should install filtering device or exhaust in flowmeter installation, the fluid must be flowing from down to up, if the fluid flow from top to bottom, then the flowmeter can not work. If the measured medium is pulsating flow, it should be appropriate to the size of the buffer device is arranged in the downstream, such as surge tank to eliminate pulsation.

          3, in order to check the meter zero and disassembly and maintenance and debugging, should stop valve and bypass valve installed in the upstream and downstream flow meter.

          4, an instrument according to the provisions after installation, should close the flow meter on the downstream shut-off valve, check again with the two meter instrument wiring, error free, open the two meter power supply is the instantaneous flow rate should be zero.

          Seven, product maintenance:

          1, in the process of long-term use, the pipeline inevitably there will be ferromagnetic impurity adsorption on the float, it will float stuck or affect the measurement accuracy, from time to time to clean the sensor float; if the installation of magnetic filters should be cleaned regularly.

          2, the instrument indicator with electronic components, instrument wiring or demolition of housing, to housing screws, must ensure sealing, prevent impurities, or other material into the water, and also to ensure reliable earthing of the meter casing.

          3, the instrument is installed, in use, should pay attention to:

          When the valve is opened to avoid the formation of pressure shock makes the float slamming limiting device, causing damage to the instrument, slowly open the valve!

          The measurement of gas meter is equipped with gas damper, Zui to decrease the float concussion; to ensure the stability of the float, a throttle valve can be installed in the instrument export.

          4, for the remote type instrument, we must first ensure that the instrument wiring correctly, keeps power; for dangerous situations, must choose the explosion-proof, and the installation and use of proof required by the.

          Eight, matters needing attention:

          1, the instrument used, should slowly open the valve to open the upstream and downstream of the flowmeter, flow regulating valve. The instrument stop should be used to slowly close the upstream valve, then close the meter downstream flow regulating valve.

          2, the instrument indication in line to see, according to the height of the float rises at the present value of float gauge reading.

          3, when the cone tube and float dirt, should be cleaned.

          Error 4, regular check meter, once beyond the prescribed error, should replace the float and cone tube, or re calibration to get better precision.

          5, the measured fluid and flowmeter calibration medium is uniform, the need for showing the value according to the revised. Represented by the formula QS=QN = Qn = QS actual flow flowmeter showing the value of P n = flowmeter calibration medium density s = density of measured medium f = float material density.


          Nine, the measuring range and the pressure loss:

          Decay path

          Common path

          measuring range

          Zui high pressure loss

          DN (mm)

          DN (mm)

          The air (m3/h)

          Water (L/h)

          The air (KPa)

          Water (KPa)

          Fifteen

          Fifteen

          0.05-0.5

          1.6-16

          Seven

          Six point four

          0.07-0.7

          2.5-25

          Seven point one

          Six point five

          0.11-1.1

          4.0-40

          Seven point two

          Six point five

          0.18-1.8

          6.0-60

          Seven point three

          Six point six

          0.28-2.8

          10-100

          Seven point five

          Six point six

          0.40-4.0

          16-160

          Eight

          Six point eight

          0.70-7.0

          25-250

          Ten point eight

          Seven point two

          1.00-10

          40-400

          Ten

          Eight point six

          1.60-16

          60-600

          Fourteen

          Eleven point one

          Twenty-five

          -

          80-800

          -

          Fourteen

          Twenty-five

          3.00-30

          100-1000

          Seven point seven

          Seven

          4.50-45

          160-1600

          Eight point eight

          Eight

          7.00-70

          250-2500

          Twelve

          Ten point eight

          11-110

          400-4000

          Nineteen

          Fifteen point eight

          Fifty

          -

          500-5000

          -

          Sixteen point two

          Fifty

          18-180

          600-6000

          Eight point six

          Eight point one

          25-250

          1000-10000

          Ten point four

          Eleven

          Eighty

          40-400

          1600-16000

          Twelve point six

          Seventeen

          Eighty

          50-500

          2000-20000

          Fifteen point five

          Six point three

          One hundred

          75-750

          2500-25000

          Seventeen Point Two

          Eight point one

          One hundred

          100-1000

          4000-40000

          -

          Nine point five

          One hundred and twenty-five

          160-1600

          6000-60000

          -

          Ten

          One hundred and twenty-five

          250-2500

          8000-80000

          -

          Sixteen

          One hundred and fifty

          -

          10000-100000

          -

          Twenty


          300-3000

          12-120m3/h

          -

          Twenty


          400-4000

          15-150m3/h

          -

          Twenty-five

          10, encoding selection:

          Specification code

          Encoding instructions

          The name of the factory

          ZW

          Zhongwei control

          Instrument types

          LZ

          Metal tube rotameter

          structural style

          /

          In the next

          H1

          The left into the right

          H2

          Right into the left out

          AA

          The side into the side

          LA

          The bottom side

          S

          Threaded connection

          M

          Clamp connection (sanitary polishing tube)

          Size code

          - XXX

          Cases: Fifteen Express DN15

          The measuring tube material

          R1

          1Cr18Ni9Ti , Three hundred and four

          R0

          0cr18Ni12M02Ti , Three hundred and sixteen

          RL

          316L

          RP

          (PTFE F-lined )

          Ni

          (Hasloy Hastelloy C)

          Ti

          (TitHXium titanium alloy )

          Media type

          L

          liquid

          G

          Gas

            working temperature 

          H1

          - 40 C -100 C

          H2

          - 80 C -250 C

          Rated pressure

          One point six

          1.6MPa

          Four

          4.0MPa

          Sixteen

          16MPa

          Twenty-five

          25MPa

          Additional structure

          O

          nothing

          Z

          Damping type

          T

          Jacket

          H

          High temperature type

          Y

          High pressure type

          Form indicator

          M1

          Local indication

          M2

          Intelligent

          M3

          Intelligent ( Flameproof )

          The output signal in the communication

          N

          nothing

          A

          4-20mA

          H

          4-20mA+Hart

          Alarm controller

          K1

          The upper limit alarm

          K2

          Alarm

          K12

          The upper and lower limit alarm

          Explosion proof type

          E1

          Intrinsically safe EX IaCT5 Square shell

          E2

          Flameproof EXiibt4 Park Housing

          Power supply

          Zero

          24VDC (can be omitted )

          Two

          220VAC

          Three

          Three point six Volt lithium battery

          Eleven, design selection and ordering information:

          1, please provide the pipe size, wall thickness, material requirements and accuracy requirements;

          2, please provide the liquid or gas, such as the name, commonly used commonly used temperature, working pressure, common flow, density, viscosity etc.;

          3, choose anti-corrosion type, should indicate the measured corrosion and concentration etc.;

          4, if there are special to show, please contact our sales department.

          Customer service service commitment:

          1, our series of metal tube flowmeter series product quality problems within twelve months, responsible for free maintenance.

          2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.

          3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.

          4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.

          5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.