        2. Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.

          Health type turbine flowmeter

          6衞生型渦(wo)輪(lun)流(liu)量計(ji)01.jpg
          6衞(wei)生(sheng)型渦輪流量計(ji).jpg
          • 6衞生型渦輪(lun)流(liu)量計(ji)01.jpg
          • 6衞(wei)生型(xing)渦(wo)輪(lun)流量計(ji).jpg
          Health (clamp) of turbine flowmeter is fast loading type (remove) simple installation, good maintena…

          Description:

          Products overview:
          ZW - LWS seriesHealth type turbine flowmeterIs made from stainless steel (316 l), machine core part USES special material, has good corrosion resistance and rust resistance.The whole table structure break through the traditional process, the use of foreign advanced structure optimization design, greatly improving the precision of the instrument and repeatability.Turbine flowmeter specially designed for the pharmaceutical, beverage industry, connected by fast loading type structure, convenient cleaning, LWS series has reached the international similar product standards, is an ideal instrument health industry.
          Second, the working principle:
          ZW - LWS seriesHealth type turbine flowmeter is when the fluid flows through the sensor shell, because of the impeller blade and flow to a certain Angle, the fluid force makes the blade with rotational torque, to overcome the friction torque and fluid resistance, blade rotation speed stability after the moment balance, under certain conditions, the speed is proportional to the velocity of flow, because there are magnetic conductivity blade, it is in the signal detector (composed of * magnetic steel and coil) magnetic field, rotating blade cutting lines, periodically changing coil magnetic flux, so that the coil ends of inductive electric pulse signal, the signal after amplifier amplification plastic, form a certain amplitude of continuous rectangular pulse wave, can be spread far to display instrument, show the instantaneous flow and cumulative amount of the fluid.Within the scope of a certain flow, pulse frequency f and flows through the sensor of fluid is proportional to the instantaneous flow rate Q, flow equation is: Q = 3600 x f/k;Type:
          F - pulse frequency (Hz);
          K - the instrument coefficient of sensor 1 / m3, given by the check list.If [1 / L] as the unit
          Q - fluid transient flow (working conditions) (m3 / h),
          3600 - conversion factor.
          Coefficient of each sensor of the instrument in the calibration certificate will be completed by the manufacturer, set into the display instrument of form a complete set of k value, can show the instantaneous flow and cumulative total.
          Applications:
          1, the pharmaceutical industry: physiological saline, glucose infusion products such as water, filling and metering;
          2, food and beverage industry, vegetable juice, juice, beer filling and measurement of liquid food.
          Four, the main features:
          1, sensor is cemented carbide bearing thrust type, not only guarantee the accuracy, and improve the wear resistance.
          2, simple structure, strong and tear open outfit is convenient.
          3, wide measuring range, low threshold velocity.
          4, small pressure loss, good repeatability, high precision.
          5, have a high resistance to electromagnetic interference and vibration resistance.
          Five, the technical parameters:
          1, meter diameter: 4, 6, 10, 15, 20, 25, 32, 40, 50;
          2, precision grade, plus or minus 1%, plus or minus 0.2%, plus or minus 0.5% R R R (special);
          3, range than: ";1:15.1;
          4, instrument material: 316 (L) stainless steel;
          5, measured medium temperature (℃) : - 20 ~ + 120 ℃;
          6, the environmental conditions: temperature - 10 ~ + 55 ℃, relative humidity 5% ~ 90%, atmospheric pressure of 86 ~ 106 kpa;
          7, output signal, sensor, pulse frequency signal, low level high level 8 V or 0.8 V or less;
          Transmitter: two wire system 4 ~ 20 madc current signal;
          8, power supply, sensor: + 12 VDC and + 24 VDC (optional);
          Transmitter: + 24 VDC;
          Display type: instrument built-in 3.2 V lithium batteries;
          9, signal transmission line: STVPV3 x 0.3 (three-wire system), 2 x 0.3 (two-wire system);
          10 and transmission distance: 1000 m or less;
          11, signal interface: basic: hausmann joint or take three core cable;Explosion-proof type: female M20 x 1.5;
          12, explosion-proof level: basic: not explosion-proof products;Explosion-proof type: ExdIIBT6;
          13, protection grade: IP65.
          Six, the installation place:
          1, the installation site should comply with the environmental temperature at 25 ~ 55 ℃ scope, humidity < 80% RH;
          2, well ventilated, avoid sun and rain;
          3, avoid in piping vibration or the place of stress;
          4, avoid easily affected by the strong thermal radiation and radioactive places;
          5, must avoid the outside strong electromagnetic field disturbance to the detection signal.If unavoidable, should be set on the amplifier of the flowmeter (sensor) shield and other measures to eliminate interference;
          6, in the places where requires explosion-proof, and isolation amplifier should be adopted;
          7, the installation position should consider ease of installation, operation, maintenance.

          Seven, installation reasons may lead to the problem:
          1, the length of straight pipe upstream or downstream is insufficient;
          2, instrument measuring pipe diameter and pipe diameter deviation;
          3, install different heart, gasket convex tube;
          4, instrument going backward;
          5, detecting element is covered by impurities;
          6, reduce the detection sensitivity, small leakage flow meter;
          7, pipeline leak (installed in underground pipeline, for example, small leakage was found), valve leakage, by-pass valve leakage cause cumulative flow smaller (total);
          8, there are two phase flow, pulsating flow influence the accurate measurement.
          Eight, wiring and grounding considerations:
          Wiring matters needing attention
          1, using a full cable as soon as possible.
          2, should as far as possible away from electrical noise (such as power transformer, electric motor and the power cord), avoid parallel to the power the power cord wiring.
          3, Suggestions in the end of the thick wire adopts the tin welding clamping lugs.
          4, for the waterproof and mechanical damage, the cable into the metal tube inside, but may not have high power transmission cables, within the same catheter (a transmission cable transmission of zui power is greater than the flowmeter signal transmission cables zui small power 10 times, both cannot be installed on the same catheter).
          5, the existing strong magnetic field outside the area, should make the axis of the detection device with the outside world vertical or the direction of the magnetic flux of the magnetic field with high permeability material for shielding flow sensor or external magnetic source.
          6, explosion-proof type turbine flow sensor cable connection, must strictly abide by the relevant standards of explosion-proof amplifier.
          Grounding problem
          1, the shielding wire can only be grounded at one end, on display instrument grounding.
          2, reliable grounding should be good, explosion-proof type grounding resistance should be less than 10 Ω.
          The use of turbine flow time must pay attention to the points:
          1, requires clean measured medium, low viscosity, corrosion resistance is small, do not contain impurities, in order to reduce the wear of bearing.If the liquid to be measured a grudge or containing gas, the flowmeter before venting device.In order to avoid damage of impurity in the fluid into the transmitter devious, and in order to prevent turbine stuck, add filters when necessary.
          2, the installation of the flowmeter should avoid vibration, avoid magnetic field and thermal radiation.
          3, medium density and viscosity changes have an impact on flow value, should be revised if necessary.

          Nine, flow range and working pressure:

          Meter diameter(mm)

          Normal flow range(m3/h)

          Expand the flow range(m3/h)

          Conventional resistance pressure(MPa)

          DN 4

          0.04~0.25

          0.04~0.4

          1.0

          DN 6

          0.1~0.6

          0.06~0.6

          1.0

          DN 10

          0.2~1.2

          0.15~1.5

          1.0

          DN 15

          0.6~6

          0.4~8

          1.0

          DN 20

          0.8~8

          0.45~9

          1.0

          DN 25

          1~10

          0.5~10

          1.0

          DN 32

          1.5~15

          0.8~15

          1.0

          DN 40

          2~20

          1~20

          1.0

          DN 50

          4~40

          2~40

          1.0

          Ten, parameter table:

          Instrument model

          ZW-LWS-N

          ZW-LWS-A

          ZW-LWS-B

          ZW-LWS- C

          Signal output

          pulse

          4-20mA

          There is no

          optional4-20mA/pulse

          Power supply

          +24VDC±15%

          +24VDC±15%

          The lithium battery

          24VDC±15%

          Communication interface

          There is no

          There is no

          There is no

          optionalRS485

          Precision grade

          1.0 ~ 0.5level

          1.0 ~ 0.5level

          Measuring range

          The standard range

          Standard range or extension

          display

          There is no

          There are

          Instrument material

          optional304SSor316LSS

          optional304SSor316LSS

          Explosion-proof grade

          optionalExdIIBT6orExiaIICT4

          ExdIIBT6orExiaIICT4

          Protection grade

          IP60

          IP65

          The connection method

          Clamp connection

          Clamp connection

          Stress levels

          1MPa

          1MPa

          The machine power consumption

          <1W

          <1W

          Instrument drift diameter

          DN4-DN250

          DN4-DN250

          Medium temperature

          - 20℃~ 120℃

          - 20℃~ 120℃

          The environment temperature

          - 20℃~ 60℃

          - 20℃~ 60℃

          Eleven, selection of coding:

          model

          Instructions (in the wei and control)

          ZW-LWS

          -

          /□

          /□

          /□

          /□

          Nominal diameter

          4

          4mm

          6

          6mm

          10

          10mm

          15

          5mm

          20

          20mm

          25

          25mm

          32

          32mm

          40

          40mm

          50

          50mm

          type

          N

          The sensor type:+12Vor24VPower supply, signal pulse output three wire system

          A

          Transmitter type:+24VThe power supply, and two wire output4~20mA

          B

          Intelligent: lithium-ion batteries, the scene show no signal output

          C

          Intelligent:+24VPower supply, the scene display and output two wire4~20mA

          C1

          Intelligent:+24VDisplay with a power supply, the sceneRS485Communication protocol

          C2

          Intelligent:+24VDisplay with a power supply, the sceneHARTCommunication protocol

          Precision grade

          05

          0.5level

          10

          1.0level

          02

          0.2level(Negotiate orders)

          The turbine type

          W

          Extend the measuring range

          S

          The standard measurement range

          explosion-proof

          N

          The explosion-proof type

          E

          Explosion-proof type,ExdⅡCT4orExdⅡBT6

          Twelve, designing order selection guidelines:

          1, instrument selection, as far as possible not to use the work flow in the lower limit value, so the meter diameter should be as small as possible, in order to obtain a larger flow rate and flow range.

          2, the flowmeter should be used in the technical parameters of medium pressure and temperature range.Don't deliberately choose the high pressure level and ultra-high temperature instrument, should be selected according to the actual work pressure and temperature instruments, which had higher prices.

          3, in the explosive dangerous location, should choose explosion-proof type flowmeter.

          4, the lower limit of flowmeter flow depends on the operation condition of the medium density and kinematic viscosity, the maximum flow is generally not affected by medium pressure and temperature, so to determine the flow range as long as you determine the actual minimum flow can be available.Calculate the minimum flow rate, flow range check table to determine the appropriate diameter.

          After-sales service commitment:

          1, from the date of signing of the contract, I in the way provided for products of the company offers free maintenance and maintenance service, commitment to lifelong maintenance service;

          2, jiangsu wei measurement and control instrument co., LTD. Sales manager will be in regular contact with customers, understand the usage of products, and solve the problems of the customers to use in the process of produce, free of charge to provide technical support;

          3 the man-made damage is found, the warranty period, our company is responsible for the maintenance, and the resulting maintenance fee;

          4, product quality problems or are not satisfied with product, the user can choose unconditional return, wei tt&c don't charge any fees, appear quality problem, bear the freight back and forth.