          Compensation conductor

          補償(chang)導線(xian).jpg
          • 補(bu)償(chang)導線(xian).jpg
          Compensation conductor should be divided into extension type and compensation type two kinds, fluori…

          Description:

          An overview, cables:
          Compensation wires and compensation cables, to a certain temperature range (including temperature) with the matched the thermocouple thermoelectric emfs values the same couple or more with insulated wire or cable, use them to connect the thermocouple and measuring devices, to compensate them with the error produced by the temperature change of the thermocouple junction, compensation wires and compensation cables are divided into extension type and compensation type two kinds, fluorine plastic wire or cable and silicon rubber insulation resistance to high temperature compensation is more high temperature resistant, cold resistant, resistant to acid and alkali oil and water, don't delay burning, anti-aging and other advantages, the products are widely used in petroleum, chemical industry, electric power, metallurgy, medicine, textile and other factories and scientific research departments in the temperature measurement and control system.
          Second, the compensating conductor standards:
          GB/T4989-94 (equivalent to the IEC584-3 standard)
          Three, compensation conductor used features:
          1, the highest working temperature conductor: 70 ℃ polyvinyl chloride (PVC) 200 ℃ and 180 ℃ 105 ℃ silicone rubber fluorine plastic meltability polytetrafluoroethylene (PTFE) 260 ℃
          2, the lowest temperature:
          PVC sheathed: fixed installation to 40 ℃, the fixed installation to 15 ℃.Fluorine plastic and silicone rubber sheath: fixed installation - 60 ℃, the fixed installation - 20 ℃.
          3, cable allows bending radius: the minimum armored cable is 6 times of overall diameter;Copper tape screened or steel tape armoured cable minimum 12 times of cable diameter;Fluorine plastic insulation and sheath minimum 10 times of cable diameter.
          Four, compensation conductor should be the basic model and name:

          model

          Products name said

          KX-GS-VV

          PVC insulated PVC sheathed general in dividing precision grade K thermocouple compensating cable

          KX-GS-VVP

          PVC insulated PVC sheathed wire braided total screen precision grade K is commonly used in dividing thermocouple compensating cable

          KX-GS-VPV

          PVC insulated PVC sheathed wire woven on screen in general by the level of precision indexing number K thermocouple with compensation cables

          KX-GS-VPVP

          PVC insulated PVC sheathed wire woven on total screen is usually in dividing precision grade K thermocouple with compensation cables

          KX-HS-FF

          Fluorine plastic insulation and sheath heat by the level of precision index number K thermocouple with compensation cables

          KX-HS-FFP

          Fluorine plastic insulated and sheathed wire braided total screen heat by the level of precision indexing number K thermocouple with compensation cables

          KX-HS-FPF

          Fluorine plastic insulated and sheathed wire weaving on screen heat by the level of precision indexing number K thermocouple compensating cable

          KX-HS-FPFP

          Fluorine plastic insulated and sheathed wire weaving on total screen heat in dividing precision grade K thermocouple compensating cable

          KX-HS-FG

          Fluorine plastic insulation silicone rubber sheath heat by the level of precision index number K thermocouple with compensation cables

          KX-HS-FGP

          Fluorine plastic insulation silicone rubber sheath copper wire braided total screen heat in dividing precision grade K thermocouple compensating cable

          KX-HS-FPG

          Fluorine plastic insulation silicone rubber sheath copper wire woven on screen heat by the level of precision indexing number K thermocouple compensating cable

          KX-HS-FPGP

          Fluorine plastic insulation silicone rubber sheath copper wire woven on total screen heat in dividing precision grade K thermocouple compensating cable

          KX-HS-FV

          Fluorine plastic insulated PVC sheathed heat by the level of precision index number K thermocouple with compensation cables

          KX-HS-FVP

          Fluorine plastic insulated PVC sheathed wire braided total screen heat by the level of precision indexing number K thermocouple with compensation cables

          KX-HS-FPV

          Fluorine plastic insulated PVC sheathed wire woven on screen heat by the level of precision indexing number K thermocouple compensating cable

          KX-HS-FPVP

          Fluorine plastic insulated PVC sheathed wire woven on total screen heat in dividing precision grade K thermocouple compensating cable

          KX-HS-GG

          Silicone rubber insulated and sheathed heat by the level of precision index number K thermocouple with compensation cables

          KX-HS-GGP

          Silicone rubber insulated and sheathed wire weaving total screen heat in dividing precision grade K thermocouple compensating cable

          KX-HS-GPG

          Silicone rubber insulated and sheathed wire weaving on screen heat by the level of precision indexing number K thermocouple compensating cable

          KX-HS-GPGP

          Silicone rubber insulated and sheathed wire weaving on total screen heat in dividing precision grade K thermocouple compensating cable

          Note: 1, the above models only list the KX, other such as SC, KC, EX, BC, TX, JX need to change the first model;
          2, before this Ann model compensating cable type charging "ia";
          3, flame retardant, compensation cable type filling before "out";If you need armoured can refill "22" after the model;If you want to block, can indicate shielding in style: P, P1 tin plated copper wire, copper wire P2 copper strip, P3 lu: su composite film;Conductor for multiple strands of soft core, should inject "R" after the model.
          4, PTFE ZR190 for imported materials, heat-resistant 260 ℃.
          Five, compensation conductor should be the main technical indicators:

          Compensation conductor model

          With thermocouple

          Thermocouple index number

          Compensating lead wire

          Insulating layer coloring

          The anode

          The cathode

          The anode

          The cathode

          SC

          10 - platinum platinum rhodium thermocouple

          S

          SPC (copper)

          SNC (copper, nickel)

          red

          green

          RC

          13 - platinum rhodium platinum thermocouple

          R

          RPC (copper)

          The RNC (copper, nickel)

          red

          green

          KCA

          Nickel chrome - nickel silicon thermocouple

          K

          KPCA (iron)

          KNCA (copper, nickel)

          red

          blue

          KCB

          Kleiner perkins caufield & byers (copper)

          KNCB (copper, nickel)

          red

          blue

          KX

          KPX (nickel chrome)

          KNX (nickel silicon)

          red

          black

          NC

          Nickel chromium silicon - nickel silicon thermocouple

          N

          NPC (iron)

          NNC (copper, nickel)

          red

          grey

          NX

          NPX (nickel chromium silicon)

          NNX (nickel silicon)

          red

          grey

          EX

          Copper nickel chrome - nickel thermocouple

          E

          EPX (nickel chrome)

          ENX (copper, nickel)

          red

          brown

          JX

          Iron, copper and nickel thermocouple

          J

          JPX (iron)

          JNX (copper, nickel)

          red

          The purple

          TX

          Copper, copper nickel thermocouple

          T

          TPX (copper)

          TNX (copper, nickel)

          red

          white

          Note: type the first letter and the thermocouple corresponding to the index, the second letter in "C" said compensation conductor, the letter "X" said compensation conductor should be extended type.SC type can be compensation conductor with R type degree thermocouple.